DTS 3681
SIDE MOUNT COOLING UNITS
20000-24000 Btu/h
Our DTS 3681 (NEMA Type 4/4x) stainless steel cooling units have the largest capacity at almost 2 Tons. These units are ideally suited for high temperature, high ambient environments. Housing: stainless steel 304. Cover: stainless steel 304
Features
ERP Efficiency Certified
As a component of the Kyoto Protocol to reduce carbon monoxide emissions, the European Energy Related Products (ERP) Directive includes an efficiency rating for fans. Pfannenberg proudly utilizes components which adhere to these requirements.
Thermal Expansion Valve
Regulates the flow of refrigerant based on thermal demand for efficient performance over the entire operating temperature range.
Closed Loop Design
Designed to isolate the external ambient air from the internally conditioned air eliminating the risk of contaminants entering the cabinet.
Hermetically Sealed Compressor
The absence of any refrigerant fill valves eliminates leak paths. Recharging is never needed. 100% cooling capacity efficiency is ensured.
Pressure Overload Protection
High pressure cutout switch ensures safety by shutting off the compressor in the event of excessive pressure appearing in the refrigeration circuit.
High Cooling Capacity
The largest capacity cooling unit for high heat load requirements. High cfm fan on evaporator side for generous air movement through the enclosure.
Corrosion Protection
Outdoor and wash-down units have a special coating on pipes and coils on the ambient side of the unit to provide maximum protection from saltwater, sour gas, and other corrosive substances.
High Airflow Backward Curve Impeller Fan
Provides high airflow in a long lasting, single bearing design. Outperforms typical two-bearing blowers with nearly twice the lifespan.
Self Protected from Harsh Environments
Our unit is uniquely designed to protect itself in NEMA 3R, 4, and 4X environments. An example of this is the location of our control electronics within our dry, cool interior circuit.
Thermal Overload Protection
Compressor and fan motors are outfitted with integral temperature switches to shut down the unit in the event of excessive temperature. This increases the operating life of the compressor by preventing thermal overload trips.
Environmentally Friendly
Utilizes HFC-free R134a refrigerant versus a blended refrigerant for easier service and minimized negative impact to the environment.
Maintenance Free Filterless Design
The wide fin spacing is less susceptible to clogging from dirt buildup which can cause the unit to work harder and hamper efficiency.
Active Condensate Management
Condensation is a natural by-product of refrigeration. The heated condensate collection pan boils this off thereby eliminating the need for drain tubes and buckets. To conserve power, this heater only activates when necessary.
Lifting Lug Ports
Threaded holes accommodate the installation of lifting lugs to facilitate safe installation.
High Ambient Performance
The DTS 3000 Series Cooling Units were designed utilizing high temperature compressors and larger condensers. Both the indoor NEMA Type 12 units and outdoor units perform very well in environments that require cooling where the maximum ambient temperature is 131° F.
Rugged Design
Powder coated steel or stainless steel cover designed for manufacturing environments. Easily painted to match enclosure or machine.
Technical Data Overview
DTS 3681 | 230 V | 400/460 V |
---|---|---|
*For the MCA (Maximum Current Ampacity) value per UL, please consult product technical datasheets available above. **SCCR rating - See user manual for instructions to achieve 50 kA (230V) or 200 kA (460V) SCCR Rating. *** (According to EN ISO 3741) |
||
PART NUMBER | 13383939158 | 13383936158 |
FREQUENCY (Hz) | 50/60 | 50/60 |
POWER CONSUMPTION (W) | 3142 | 2275/2920 |
NOMINAL (RUN) CURRENT* (@35A/35A) | 14.24 | 5.66 |
FUSE (max.)** CLASS CC | 25 | 10 |
NOISE LEVEL*** dB(A) | <73 | <73 |
WEIGHT lb (kg)(without packaging) | 240 (109) | 240 (109) |
DIMENSIONS | 65.5 in. (1665 mm) h x 19 in. (485 mm) w x 20.5 in. (520 mm) d |
Performance Curve
How to use this chart:
Example: @ 95°F (ambient, X-axis), @ 95°F (internal, diagonal lines)
= 21788 Btu/h cooling capacity (Y-axis)

Additional Data
AMBIENT TEMPERATURE RANGE | + 32°F … + 131°F / + 0°C … + 55°C | |
CONTROL RANGE (adjustable) | SC | + 77°F … + 113°F / + 25°C … + 45°C; factory setting + 95°F / + 35°C |
REFRIGERANT | type | R134a |
quantity | 1300g | |
CONDENSATE MANAGEMENT | active condensate evaporation system with safety overflow | |
PROTECTION SYSTEM ACCORDING TO NEMA TYPE | NEMA Type 4/4x(against enclosure when properly installed) | |
NEMA 1 towards the surroundings when properly installed |
Latest Posts